Variable frequency drive sizing before sizing a variable frequency drive before selecting the size of a variable frequency drive vfd, it is necessary to generally know the working environment, the target work and if the performance and functions are satisfied. Two versions are available, one for online users, and the other can be installed on a pc. The wires going out the motor need to be sized based off the current and voltage that will be carried on them. Cable sizing, sustained current capacity bs 7671 wiring regulations, voltage drop clctr 50480, fault level and impedance iec 60909. Instant answers to help better navigate your job site calculations. To calculate cable size and to assist engineers during project expansion. The new vfd supplement catalog is available from hwc. This is the demonstration page for our cable calculator application which can be downloaded and installed on your website. Actual current carrying capacity of cable derating factor current capacity of cable in ground,air as per cable catalogueno of runs per phase 0. The following calculator computes the resistance, inductance, inductive reactance, capacitance, charging current, and surge impedance for medium voltage shielded power cables.
These design requirements can be userdefined or automatically determined from load flow, short circuit, and protective device calculation results. The nameplate in figure 1 shows that motor current is based on the input voltage. Calculation tools for low voltage electrical network. Cables used with variable frequency drives vfds need to match the operating environment and other components in the system. Drivesize can also be used to compute network harmonics and to create dimensioning documents. Step 1 size the overcurrent device in accordance with 210. Sizing the size of the power wires and fuses that are going to the vfd should be sized to handle the overall load and voltage rating of system. Cable length longer runs may require upsizing cables to reduce voltage drop because voltage drop is directly proportional to cable length. Consult with an engineer if your application requires more complex calculations. Hello, i am working on a 300 hp vfd application, running a pump. These breakers are all inversetime breakers, and in referencing the code, i am using sections 240. In this cable selector, you will not find constructions where copper content has been compromised or the insulation material does not stand up to the challenges of vfd environments. A vfd cable will experience high voltage spikes under normal operating conditions as a result of the highfrequency switching technology used in the drive. The cable should be sized for the motor full load current plus overload, without allowance for harmonic content.
Our vfds handle both low voltage and medium voltage applications, with a wide range of power ratings. These two nec rules require the overcurrent device breaker or fuse be sized no less than 100% of the noncontinuous load, plus 125% of the continuous load. The lapp group released a new online engineering calculator that helps users select variable frequency drive vfd cables. Vfd sizing considerations are continuous current, input. Tough challenges call for innovative solutions, and general cable is your worldwide source for new products and a wide range of industryleading industrial cables. Variable frequency drive vfd cable selection guide anixter. Electrical calculation tools is a set of 7 computer aided online tools designed to help you. Variable frequency drive vfd cables variable frequency drives vfd, also known as variablespeed or adjustablespeed drives are used to power ac motors in a variety of industrial motion control, commercial flowpumping, and extrusion applications. Cable energy withstand based on the protective devices letthrough energy. Cable size calculation spreadsheet electrical engineering portal. We have a fully fledged application where you can size lv and mv cables up to 33 kv, current capacity in accordance with bs 7671, era 6930 and iec 60502 and with clear easy to read calculations and reports. Overload protection in multimotor applications with vfd motor protection circuit breakers are now suitable for this application customer need many applications can use multiple motors of the same capacity operating in parallel at the same speed. S4, 150sthr, 3 phase, 415v cable length 25 mtr festoontrailing cable. The vfd continuous current shall be higher than the motors current at maximum load.
During the electrical design electricalom acts interactively and indicates to the user useful. Etap cable sizing software provides various options which can be used for design requirements. Lets begin with the basics by learning how to read a motor nameplate. A motor that operates under worst case conditions at 80% fla. Home resources calculators simpull cable pull calculator. We provide a complete line of cables for variable frequency drives vfd in both unarmored and armored designs as well as in many power. How to size a cable correctly stepbystep comprehensive guide. The current return to the variable frequency drive main power circuit is mainly through two paths. Motor cable sizing whatever the circuit motor, lighting, other circuit the software you use is made to check following criteria for cable sizing. We have a motor control center mcc where we removed the combo starters and landed the wire directly to the circuit breakers and then to a variable frequency drive vfd. Conductor ampacities are based on nec 2008, table 310.
It may be more convenient to calculate the maximum length of a cable for a particular conductor size given a maximum permissible voltage drop e. Select the properly sized vfd cables for your specific installation based on application. Etap cable sizing study module calculates optimal and alternative cable sizes for phase conductors. Variablefrequency drive systems inherently expose their output cables to harsh operating conditions via high voltage spikes, amplified noise levels including electromagnetic and radio frequency interference, and challenging. Variable frequency drive cable sizing variable frequency drive power cables between the various system components are the responsibility of the installer and the size and type to be used should be selected to suit the application and on the basis of the continuous current rating of the variable frequency drive and a minimum temperature rating. Cable sizing software that calculates optimal and cable sizes for phase conductors based on load flow, short circuit, or protective device calculation results. I am confused in three phase wire size calculation please let me know exact formula for three phase wire size calculation with multicore and single core cable. The discussion, illustrations, charts and examples given in this article are intended solely to illustrate the theory and application of drive technology. The reactance for single core cables is selected from the flat, touching column in from table 30 in asnzs 3008. Electrical tools ms excel spreadsheets this section is dedicated to tools every electrical engineer can use in daily work. Cable pulling calculations generator capabilitymotor starting. Faster than the heavy full features electrical network calculation software.
Along with the cable sizing calculation results, this section also displays the required cable sized, cable ampacity, percent of voltage drop, and percent of starting voltage if cable sizing options for the corresponding requirements are checked. The cable sizing calculator uses the resistance rc from table 35 in asnzs 3008 at 75c. These spreadsheets below will make your job much more easier, alowing you to shorten the time used for endless calculations of cables, voltage drop, various selections of circuit breakers, capacitors, cable size and so on. Cable size calculations based on motor horse power hp and specified current. Cable size calculations electrical engineering portal. When using sizing software, most cable sizing programs assume that 600 percent directonline dol starting current will be required. Etaps cable sizing analysis software can compute the size of the cables based on cable shortcircuit capacity to withstand the shortcircuit current. There also exists other offline software packages that include cable sizing for example from solutions electrical uk. In such applications, you can use one variablefrequency drive vfd to control multiple motors. Coolselector2 is a free refrigeration software for download. To get started you need to know your applications voltage and either full load current or horsepower. Voltage drop calculation are required if the length of cable is large. Cable sizing calculations for phase, neutral and earthing conductors are based on the following criteria.
Always use the total length of the circuit for calculations. Its recommended to check the ampacity of a wire after doing a voltage drop calculation. A motor that operates under worst case conditions at 80% fla current flowing, only requires a vfd that can. Cable sizing software cable sizing calculation etap. Most of the major power systems analysis software packages e. These high voltage spikes can well exceed the voltage rating of the cable. Usually for voltage drop calculation according to electrical standards it is the resistivity at 100c that is used for example nf c15100. Drivesize helps to select an optimal motor, drive and transformer. It is not necessary to size the vfd to the motor fla rating if the motor application is oversized. The required cable size is the largest size from shortcircuit, overload, and shock requirements. Voltage drop is calculated and cable size increased if necessary 3. It contains current versions of our motor and drive catalog. Cablesizer a free web application for sizing cables to nec and iec standards.
Electrical ms excel spreadsheets calculations of cables, voltage. Ken fonstad, hvac sales application support principal. This calculator provides a good estimate based on industry standard calculation methods and cable manufacturing data. It offers a scientific, time saving way to select danfoss manufactured components and ensuring optimal performance in refrigeration and air conditioning systems by providing accurate technical information. Lapp group usa, variable frequency drive vfd cable selector. Electrical calculation tools schneider electric global. Selecting the right vfd cable can help ensure the drives reliability and lifecycle. Use this simple tool to calculate conduit size and fill percentage, pulling tensions, cable sidewall. Helps determine the proper wire size for an electrical circuit based on the voltage. The reactance for multicore core cables is selected from the circular conductors column in from table 30 in. Fault level withstand is calculated and cable size increased if necessary tip.
Overload protection in multimotor applications with vfd. This cable sizing calculation program allows you to calculate cable size based on electric motor minimum allowable starting voltage. Bs 7671, iee wiring regulations cable size is selected as follows. The use of parallel conductors may create more economical solutions that are easier to install and terminate for large motors of 200 hp or more minimum cable size of 10 awg. Whatever the circuit motor, lighting, other circuit the software you use is made to check following criteria for cable sizing. Vfd sizing should always be based on motor current and voltage, not hp. The following are key specifications to consider when selecting a. The results should be validated with a hand calculation or order of magnitude estimate. Hwc is a master variable frequency drive cabling supplier. Sizing conductors for vfds, defining terms and more. Motor starter type direct online, stardelta, softstart etc. The short circuit current can be specified manually or obtained from the short circuit. Display the timecurrent curves of 1 to 8 circuitbreakers. We offer a wide selection of powerflex ac and dc variable frequency drives and kinetix servo drives that are all designed for flexibility, productivity, and ease of use.
The electrical design engineer must use only spuapproved electrical analysis software. Oct 28, 2015 chris daulton, global industrial marketing manager for belden, added that the cables voltage must be able to support those of the vfd, so their ratings should be equal or higher than the vfd. Awg size selection chart per nec nec allowable conductor ampacity regulatory codes drive hp 230v 3o awg 460v 3o awg 575v 3o awg. Cable sizing for vfd application lionelhutz electrical 10 nov 17 14. Use effective 300% or 100% ground and shielded designs for improved protection against electrical noise and electromagnetic interference emi. Electrical design, cable sizing and certification software. Cable sizing for vfd application eeprom electrical op 30 sep 17 16. Coolselector2 features unbiased calculations for the selection of.